TYMSERVE 2000
FREE TS2000-ALL (INTERNAL CLOCK)"
::= {ntpVars 5}
ntpRefTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NTP Reference Timestamp. This is the time,
in timestamp format (converted to octet string),
when the local clock was last updated. If the
local clock has never been synchronized, the value
is zero."
::= {ntpVars 6}
ntpVersion OBJECT-TYPE
SYNTAX INTEGER (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NTP Version. This is an integer indicating the
version number of the sender. NTP messages will
always be sent with the current version number
NTP.VERSION and will always be accepted if the
version number matches NTP.VERSION. Exceptions
may be advised on a case-by-case basis at times
when the version number is changed.
================================================
NOTE: The TS2000 series was implemented using
NTP version 3. However, the TS2000 series will
accept a version of 2 or 3 and return the same
version number in the packet. This behavior is
subject to change."
::= {ntpVars 7}
ts2TimeSrcUTCOffset OBJECT-TYPE
SYNTAX INTEGER (-11..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This variable is valid for the TS2000-IRIG
or the TS2000-GPS when operating in IRIG decoder
mode. The variable represents the offset of the input
timecode from UTC in signed hours. The allowable
values for this variable are -11 through 12.If this
variable is queried on the TS2000-ACTS it will
return 0."
::= {ts2Vars 1}
Datum Inc, Bancomm Div. TYMSERVE 2000 Manual