14
6.4 Changing the set pressure
IMPORTANT: WHEN ADJUSTING SET PRESSURE, DO NOT EXCEED THE PRESSURE
CAPABLE OF THE DYNADRIVE IN THE GIVEN INSTALLATION. REFERENCE TO AS/NZS
3500/2003 (OR LOCAL EQUIVALENT) SHOULD ALSO BE CONSIDERED. When changing
the set pressure of DynaDrive, the pressure of the pressure tank must also be adjusted.
Refer to section 4.5 pressure tank, of the installation chapter.
The set pressure cannot be changed while the pump is running, or in automatic mode.
To change the set pressure:
• Ensure automated control is turned off. To turn the automated control off, push the
Automatic on /
manual off button.
The green
Automatic LED will turn off, see figure 6.5;
Figure 6.9
P/ N :16115 -1 B
Pset 400
Pact 400
Once the motor has slowed to a stop, press and hold the Menu button for ~ 5 seconds. The display
will change to show your current set pressure, see figure 6.10;