16
12. ChloroMatic Nipper FEATURES
12.1 CONTROLLING CHLORINE OUTPUT
65% – 09:35 AM
AUTO 0N
Figure 12.1
The CHLORINE OUTPUT controls the time that the cell is producing chlorine, as a percentage of total time that
the ChloroMatic Nipper is on. If the ChloroMatic Nipper cell is producing, it is producing at 100%, unless otherwise
altered (see sections WINTER MODE, or SPA MODE). The cell run time is referred to as “cell duty cycle”.
For example:
• If the ChloroMatic Nipper is on for 8 hours per day, and the CHLORINE OUTPUT is set to 50%: the
ChloroMatic Nipper cell duty cycle is only 4 hours, of that day;
• If the ChloroMatic Nipper is on for 8 hours per day, and the CHLORINE OUTPUT is set to 25%: the
ChloroMatic Nipper cell duty cycle is only 2 hours, of that day.
To adjust the CHLORINE OUTPUT:
70% – 09:35 AM
CHLORINE OUTPUT
Figure 12.2
> Press the menu up/down buttons to scroll to your chosen CHLORINE OUTPUT;
> The setting will change the cell duty cycle by 5% increments;
> Press
menu/setting select once your preferred CHLORINE OUTPUT is displayed;
> This will then take you back to the HOME screen.