Troubleshooting Guide
Page 34 Weather Wizard III
WIND TIPS
Wind speed reading seems lower than expected
• Check installation by spinning wing cups. If you get a reading, the wind
cups are installed correctly. They should spin more freely after an initial
break-in period of one or two weeks.
Wind speed reads 0 either all the time or intermittently
• Make sure anemometer cable is plugged into jack marked WIND on junc-
tion box.
• Check for broken wire along length of anemometer cable. Carefully check
areas where the cable has been secured.
• Check installation by spinning wind cups. If you do not get a reading, try
moving the wind cups down about 1/16 inch (1.5 mm) on the shaft.
• If you still do not get a reading, the problem is probably with the anemome-
ter. Call factory for return authorization.
Wind speed reading seems too high or too low
• Check calibration number and adjust if necessary.
Wind direction reading is dashed out
• Make sure anemometer cable is plugged into jack marked WIND on junc-
tion box.
• Check for broken wire along length of anemometer cable. Check the areas
where the cable has been secured carefully.
• If these steps do not reveal the problem, the problem is probably with the
anemometer. Call the factory for return authorization.
WIND CHILL TIPS
Wind chill reading seems too high or too low
• Check calibration number for temperature and wind speed. Adjust if neces-
sary.