Detailed Parameters
Section 4
QUANTUM
43
Shaping S1 or S2
This lets you change between the 2 different digital noise shape algorithms.
See Figure H-2 in the Appendix, pg. 82
Dither Out - All or Digital
Sets the routing of the Dither output. When All is selected, the Dither is routed to the digital
outputs and the D/A. When the Dither Out is set to Digital, the dithered signal is sent to the
digital outputs and the full 24-bit output is sent to the D/A.
4.16 Output (cont.)