RESPONSIBILITIES OF THE INSTALLER
Remember that anyone who sells and/or motorises doors/gates becomes the manufacturer of the automatic door/gate
machine and must therefore prepare and conserve a technical folder that contains the following documents (see Machinery
Directive Enclosure V):
• Assemblydrawingoftheautomaticdoor/gate;
• Electricalconnectionandcontrolcircuitwiringdiagram;
• Riskanalysisincluding:alistoftheessentialsafetyrequirementsprovidedinMachineryDirectiveEnclosureI;alistoftherisks
posed by the door/gate and the description of the solutions adopted.
• Keeptheseoperatinginstructionsinasafeplacetogetherwiththeinstructionsforalltheothercomponents;
• Preparetheseoperatinginstructionsandgeneralsafetywarnings(forthecompletionoftheseoperatinginstructions)and
deliver a copy to the final user;
• Filloutthemaintenanceregisteranddeliveracopytothefinaluser;
• DrafttheCEdeclarationofconformityanddeliveracopytothefinaluser;
• FilloutthecompleteCElabelorplateandapplyittothedoor/gate.
Note: The technical folder must be conserved for inspection by the competent national authorities for at least ten years from
the date construction of the automatic door/gate.
“OPERATING CONTROL” table
Type of use
Type of control
Informed users
(private areas)
Informed users
(public areas)
Uninformed users
Person-present control Pushbutton control Pushbutton control with key
The person-present control is
not possible
Pulse control with the gate in
sight
Force limitation
or
presence detectors
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Pulse control with the gate not
in sight
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Automatic control
(i.e. control with
timed closing)
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Pos. Description
1 102 Lux key selector
2 Remote-control
3 Pilly 60 column
4 Safety edge
5 Electric lock
6 FLIC/rad digital
selector
7 104 Lux series
photocells
8 LOOK
9 Lumy flashing light
10 Control box
“EXAMPLE OF TYPICAL INSTALLATION” picture
WARNING In case a little pedestrian door is installed on the gate and it may be opened while the gate moves, it is necessary
to adopt a limit switch to grant that door closing while the gate moves and to maintain this protective function also in case of failure
of this security limit switch.