EasyManuals Logo

Dea NET724N User Manual

Dea NET724N
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
38
7 Restoring default parameters
WARNING At the end of the procedure, the display will be blocked on ashing ” and motor stroke learning must be carried out
again before any other operation can be carried out.
7.1 Restoring operating parameters
1. Scroll through the parameters with the buttons
and
until the display shows P007;
2. Con rm by pressing on the
key;
3. When
” is ashing, press the key for a few
seconds;
4. Release the
key as soon as “ ” stops ashing;
All the default values are restored except for the para-
meters from P016 to P022;
5. At the end of the operation display returns to P007.
Warning: After you restore the default parameters, you
must program the control panel again and adjust all ope-
rating parameters.
7.2 Restoring “I/O” setting (Input/Output)
1. Scroll through the parameters with the buttons
and
until the display shows P010;
2. Con rm by pressing on the
key;
3. When
” is ashing, press the key for a few
seconds;
4. Release the
key as soon as “ ” stops ashing;
All the default values only for the parameters from
P016 to P022 are restored;
5. At the end of the operation display returns to P010.
8 Locking-Unlocking access to programming
By using a “dip-switch” remote (regardless of the type of remotes already memorized) it’s possible to lock-unlock access to the program-
ming of the control panel to avoid tampering. The remote setting is the locking-unlocking code veri ed by the control board.
8.1 Locking access to programming
1. Scroll through the parameters with the buttons
and until the display shows P008;
2. Access the parameter by pressing the button
;
3. The display shows alternately the writing
to indicate that the control board
is waiting for the transmission of the block code;
4. Within 10 seconds press CH1 on the “TX Master”,
the display shows
before returning
to the list of parameters;
5. Access to programming is locked.
WARNING Programming lock/unlock can also be set via Smartphone using the DEAinstaller APP. In this case, an installer code is set
(other than zero) that can only be unlocked via APP.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dea NET724N and is the answer not in the manual?

Dea NET724N Specifications

General IconGeneral
BrandDea
ModelNET724N
CategoryGarage Door Opener
LanguageEnglish

Related product manuals