40
9 Downloading/uploading data memory
9.1 Downloading data to an external memory unit (DOWNLOAD)
1. Scroll down the parameters with
and keys until you visualize P011;
2. Press the
key, the display visualizes the word “ ashing;
3. Press the
again and continue pressing it for 5 sec (if you release it before this period, the procedure is stopped);
4. Release the
key as soon as the word “ ” stops ashing;
All the control panel con gurations (TYPE, parameters, remotes, operators stroke, etc..) are saved in the external memory unit;
Warning: If there is any data in the external memory, during the memory download they will be overwritten.
5. At the end of the operation display returns to P011.
9.2 Uploading data from an external memory unit (UPLOAD)
1. Scroll down the parameters with
and keys until you visualize P012;
2. Press the
key, the display visualizes the word “ ashing;
3. Press the
again and continue pressing for 5 sec (if you release it before this period, the procedure is stopped);
4. Release the
key as soon as the word “ ” stops ashing;
All the control panel con gurations (TYPE, parameters, remotes, operators stroke, etc..) contained in the external memory unit are
uploaded in the connected control panel;
5. At the end of the operation display returns to P012.
WARNING If you are not connected to any MEMONET units or if the connecting cable is disconnected during the data transfer operation,
the display will visualize
, then the control unit is entirely reset and the display shows the word “TYPE” ashing.
Refer to the MEMONET instruction to restore command unit functioning.
10 Inputs con guration
Where the installation requires different commands and / or additional to
the standard ones described by plan, you can con gure each input for the
operation desired (eg. START, PHOTOS, STOP, etc ...).
1. Scroll down the parameters with the
and to see that corresponding
to the desired one:
P019=for INPUT 1;
P020=for INPUT 2;
P021=for INPUT 3;
P022=for INPUT 4;
2. Con rm by pressing on the
key to get access to the parameter (eg.
P020);
3. Scroll down with the
and , keys to set the value corresponding to
the desired operation (refer to table “Input Con guration parameters” on
page 44);
4. Con rm by pressing on the
key (display shows again P020).
5. Execute the new connection to the input just recon gured.
11 Programming complete
WARNING At the end of the programming procedure, re-introduce Jumper J4, until “- - - -” is shown on the display and close the lid of
the electric box. The automatism is now in stand-by for normal operating commands.