EasyManua.ls Logo

Dea REV Series - Safety Warnings and Precautions

Dea REV Series
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
REV
Electromechanical operators
for sliding gates
Operating instructions and warnings
Index
1 Warnings Summary 19 7 Advanced Programming 29
2 Product Description 20 8 Messages shown on the Display 31
3 Technical data 20 9 Start-up 31
4 Installation and Assembly 21
9.1
Installation Test 31
5 Electrical Connections
9.2
Unlocking and manual operation 31
5.1
Electrical Connections
for 24V models
22
10 Maintenance
32
5.2
Electrical Connections
for 230V models
24
11 Product Disposal
32
6 Standard Programming 26
Product Conformity
DEA System guarantees the conformity of the product to European Directives 2006/42/CE regarding “machinery safety”,
2004/108/CE“electromagneticcompatibility”and2006/95/CE“lowvoltageelectricalequipment”.SeeDeclaration of Incorpo-
ration.
1 WARNINGS SUMMARY
Readthesewarningscarefully;failuretorespectthefollowingwarningsmaycauserisksituations.
WARNING Usingthisproductunderunusualconditionsnotforeseenbythemanufacturercancreatesituationsofdanger,and
forthisreasonalltheconditionsprescribedintheseinstructionsmustberespected.
WARNINGDEASystemremindsallusersthattheselection,positioningandinstallationofallmaterialsanddeviceswhichmake
upthecompleteautomationsystem,mustcomplywiththeEuropeanDirectives2006/42/CE(MachineryDirective),2004/108/CE
(electromagneticcompatibility),2006/95/CE(lowvoltageelectricalequipment).Inordertoensureasuitablelevelofsafety,besides
complyingwithlocalregulations,itisadvisabletocomplyalsowiththeabovementionedDirectivesinallextraEuropeancountries.
WARNING Undernocircumstancesmusttheproductbeusedinexplosiveatmospheresorsurroundingsthatmayprovecor-
rosiveanddamagepartsoftheproduct.
WARNINGToensureanappropriatelevelofelectricalsafetyalwayskeepthe230Vpowersupplycablesapart(minimum4mm
intheopenor1mmthroughinsulation)fromlowvoltagecables(motorspowersupply,controls,electriclocks,aerialandauxiliary
circuitspowersupply),andfastenthelatterwithappropriateclampsneartheterminalboards.
WARNING Allinstallation,maintenance,cleaningorrepairoperationsonanypartofthesystemmustbeperformedexclusively
byqualifiedpersonnelwiththepowersupplydisconnectedworkinginstrictcompliancewiththeelectricalstandardsandregulations
inforceinthenationofinstallation.
WARNING UsingsparepartsnotindicatedbyDEASystemand/orincorrectre-assemblycancreaterisktopeople,animalsand
propertyandalsodamagetheproduct.Forthisreason,alwaysuseonlythepartsindicatedbyDEASystemandscrupulouslyfollow
allassemblyinstructions.
WARNINGIncorrectassessmentoftheimpactforcescancauseseriousdamagetopeople,animalsorthings.DEASystem
remindstheinstallermustverifythattheimpactforces,measuredasindicatedbythestandardEN12445,areactuallybelowthe
limitssetbythestandardEN12453.
WARNINGThecomplianceoftheinternalsensingobstaclesdevicetorequirementsofEN12453isguaranteedonlyifused
inconjunctionwithmotorsfittedwithencoders.
WARNINGAnyexternalsecuritydevicesusedforcompliancewiththelimitsofimpactforcesmustbeconformtostandard
EN12978.
WARNINGIncompliancewithEUDirective2002/96/EConwasteelectricalandelectronicequipment(WEEE),thiselectrical
productshouldnotbetreatedasmunicipalmixedwaste.Pleasedisposeoftheproductandbringittothecollectionforanap-
propriatelocalmunicipalrecycling.