26
6 STANDARD PROGRAMMING
1Power Supply
Givepowersupply,thedisplayshowsthefollowingsymbols“ ”,“ ”,“ ”andthen“----”.
*Ifthecontrolpanelhasalreadybeenprogrammedandthepowerfailsorisswitchedoff-oncepowerisreturnedandaSTART
commandisgiven,thepositionresetprocedureisperformed(see“rESP”inthetable“WORKINGSTATUSMESSAGES”onpage31.
2Visualisation of inputs and operations-counter status
1. Pressthe keyfor15seconds;
2. Thedisplaywillshowrespectively:
Inputsstatus(checkit’scorrect);
Totaloperationscounter(*seeP064):
i.g.: =3x100*=3000operationsperformed
Maintenanceoperations-counter(*seeP065):
i.g.:
=5*x500=2500operationsremaining
beforethemaintenanceinterventionrequest( =
manoeuvres-counterdisabled)
3. Holddownthe
keytodisplayacyclic3options,or
releasethe buttontoexittheparameter.
3Selection type of operators ! IMPORTANT !
1. Scrolldowntheparameterswith and keysuntilyouvi-
sualiseP028;
2. Accesstheparameterbypressingthe key;
3. Verifythatthevaluecorrespondstod007(REV),otherwise,you
mustselectitbypressing and keys;
4. Confirm yourchoicebypressing the key (displayreturns
againtoP028).