Dectron, Inc. March 2012
Owners Manual
DSH/DSV/RSH/DBH/RBH Series Dehumidifier
Data subject to change without notice.
243
DRY-O-TRON® DS Series
Startup Report & Warranty Registration
Warranty void unless this form
is completed and submitted
within 1 week after startup.
See unit nameplate for the following information:
For units with air-cooled
air conditioning only:
See compressor nameplate(s) for the following information:
Installation Name:
Installation Address:
Dectron Representative Firm:
Supply
Airflow: CFM
Hot-Gas
Tube Size(s) (O.D.)
if any
Comp 1
Model #
Comp 1
Serial #
Comp 2
Model #
Comp 2
Serial #
Comp 3
Model #
Comp 3
Serial #
Comp 4
Model #
Comp 4
Serial #
Comp 5
Model #
Comp 5
Serial #
Comp 6
Model #
Comp 6
Serial #
Comp 7
Model #
Comp 7
Serial #
Comp 8
Model #
Comp 8
Serial #
Supply Blower
Belt Size (if any)
Return Blower
Belt Size (if any)
Min. Exh. Blower
Belt Size (if any)
Max. Exh. Blower
Belt Size (if any)
Unit
Model:
Unit
Serial #:
Unit
Ref #:
Cir. 1 Cir. 2 Cir. 3 Cir. 4 Cir. 5 Cir. 6 Cir. 7 Cir. 8
Liquid
Tube Size(s) (O.D.)
Maximum Allowable
Length of Tubes: ft.
if any
if any
Proper air distribution:
Proper duct design:
Proper ventilation
provided:
Vapor retarder installed
properly:
Chemicals stored in the
Mechanical Room:
Adequate service access
provided:
Vibration isolation provided:
Flex duct installed at Inlet and
Outlet of DRY-O-TRON®:
Condensate drain installed:
Condensate drain tested:
Condensate pump (if any)
installed properly:
Branch-circuit disconnect
switch installed:
Remote condenser (if any)
installed properly:
Remote operator panel (if any)
installed properly:
Outdoor temperature sensor
(if any) installed properly:
Wire connections checked for
tightness:
Startup checklists complete:
Blower rotation on 3-phase
motors correct:
Airflow and blower speed
adjusted:
Refrigerant charge OK:
Fault codes displayed on
operator panel:
Set points are at design
conditions:
Bypass damper open in room
temp. > 78° F:
Measured Airflow: cfm
Yes
No
N/A
Begin with the unit turned OFF. See safety warnings on a previous page.
page 1 of 4
See unit nameplate.
STARTUP
6.37

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dectron DRY-O-TRON Supervisaire DSV 040 and is the answer not in the manual?

Dectron DRY-O-TRON Supervisaire DSV 040 Specifications

General IconGeneral
BrandDectron
ModelDRY-O-TRON Supervisaire DSV 040
CategoryController
LanguageEnglish

Related product manuals