DelfiScan
Programming Manual
Configure Your DelfiScan
22
PROGRAM
Symbology Reading Control
Code 128 & UCC/EAN 128 Setting
M_DEFAULT
Family Code Selection
P.C
Parameter Selection Option Code
Code 128/EAN-128 Setting
SS
SS
SS
SS
SS
SS
Disable Code 128 and UCC/EAN-128
Enable Code 128 and UCC/EAN-128
Disable function code conversion
Enable function code conversion
ISBT Concatenation Off
ISBT Concatenation On
0
1
2
3
4
5
Code 128/EAN-128 Min.
Length
SS
MS
Default (01)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will
terminate this selection automatically.
FIN
(2 digits)
Code 128/EAN-128 Max.
Length
SS
MS
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then DelfiScan will
terminate this selection automatically.
FIN