Enable administrative communication
The administrative interfaces are located on the management module on the rear of
the chassis. These interfaces are for management network traffic only. Do not use
these interfaces for data traffic.
1. Connect an administrative console to the serial port on the back panel of the
system.
2.
You must have 115200 baud rate for the system to work correctly; 9600 baud rate
does not work.
Launch a terminal emulation program from your computer and configure the
following communication settings:
Table 6 Communications settings
Setting Value
Baud rate 115200
Data bits 8
Stop bits 1
Parity None
Flow control None
Emulation VT-100
3. Press Enter to activate the console.
If you do not see the prompt on your terminal to log in, then complete Step 4.
4. Verify the front blue power LED (blue square) is on. If it is not, make sure the
power cables are fully seated at both ends, and both AC sources are on.
5.
The initial username is sysadmin and the initial password is the system serial
number.
Log in to the Data Domain console using the sysadmin username.
localhost.localdomain login: sysadmin
6. Type the default password, which is the system serial number. The Product ID/SN
tag is attached beneath the power supply at the rear of the system. See the rear
panel of the system for the Product ID/SN tag.
Password: system_serial_number
Configure System for Use
32 Data Domain DD6300 System Installation Guide