Dell EMC S5200F-ON Series - User Manual

Dell EMC S5200F-ON Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
S5200F-ON Series
Setup Guide
Question and Answer IconNeed help?

Do you have a question about the Dell EMC S5200F-ON Series and is the answer not in the manual?

Dell EMC S5200F-ON Series Specifications

General IconGeneral
ModelS5200F-ON
Product TypeSwitch
Form Factor1U
Latency< 1 µs
RAM16 GB
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5% to 95% non-condensing
Product SeriesS5200F-ON Series
CategoryData Center
Power SupplyDual hot-swappable power supplies (1+1 redundancy)
CoolingFront-to-back airflow
FansHot-swappable
Operating SystemDell EMC Networking OS10
CPUIntel x86
Operating Temperature0°C to 40°C (32°F to 104°F)
ManagementCLI, Web, SNMP
Dimensions (H x W x D)1.73 in x 17.1 in x 22 in

Summary

About this guide

Regulatory

Details regulatory models and types for the S5200F-ON Series switches.

Related documents

Lists related Dell EMC documentation for the S5200F-ON Series switches.

Information symbols

Explains the icons used in the guide for notes, cautions, and warnings.

Site preparations

Site selection

Guidelines for choosing a secure installation location for network equipment.

Cabinet placement

Requirements for installing the switch in indoor cabinets for optimal environment.

Rack mounting

Instructions for grounding the equipment rack before mounting the switch.

Switch ground

Dell EMC recommendations for grounding the S5200F-ON Series switch.

Fans and airflow

Information on switch airflow configurations and ventilation requirements.

Power

Guidelines for connecting the switch to the appropriate power source.

Storing components

Proper storage guidelines for the S5200F-ON Series switch and components.

S5200 F-ON Series switch Installation

Unpack

Procedure for unpacking the S5200F-ON Series switch and verifying contents.

Ground cable

Instructions for attaching the ground cable to the switch using M4 screws.

Rack or cabinet installation

Methods for mounting the switch on a rack shelf or directly into a 19-inch rack.

Rack mount safety considerations

Safety guidelines for rack loading, power, airflow, and grounding.

One-half U front-rack installation

Instructions for installing the S5212F-ON switch using a dual-tray in a four-post rack.

One-half U switch installation

Procedure for installing one or two half-U switches into a four-post rack-mounted dual tray.

One-half U switch removal

Steps to remove the S5212F-ON switch from a dual tray.

One U ReadyRails installation

Installing the ReadyRails system for S5248F-ON, S5232F-ON, and S5224F-ON switches.

1 U Tool-less mount installation

Guide for installing rails into square-hole racks using a tool-less method.

Two-post flush-mount installation

Instructions for installing rails for two-post flush-mount configurations.

Two-post center-mount installation

Procedure for installing rails for two-post center-mount configurations.

Four-post threaded installation

Instructions for installing rails for four-post threaded rack configurations.

1 U front-rack installation

Configuring and attaching inner switch rails to the S5200F-ON Series switch.

DC power connections

Diagram and explanation of the DC power connector and wiring block.

S5212 F-ON only DC power connections

Specific DC power connection details for the S5212F-ON switch.

Optics installation

Guidelines for positioning and inserting optical transceivers into switch ports.

Optics removal

Procedure for removing optics from switch ports.

Switch power-up

Steps and checks before powering on the S5200F-ON Series switch.

After switch installation

Information on using Dell EMC or third-party software after installation.

Two U four-post rack assembly

Four-post rack mount

Safety considerations and guidelines for mounting the chassis in a four-post rack.

Chassis installation and removal

Steps for installing and removing the chassis from the rack.

Specifications

Chassis physical design

Details the physical dimensions and weight of the S5200F-ON Series chassis.

Environmental parameters

Specifies operating and storage temperature, humidity, and rack clearance.

AC power requirements

Lists AC power supply voltage, frequency, and thermal output specifications.

Maximum current draw per system

Details maximum current draw at different voltages for S5200F-ON Series switches.

Maximum power consumption

Specifies maximum power consumption for various S5200F-ON Series models.

DC power requirements

Details DC power input voltage range and maximum current at full load.

Support

Support site information

Guidance on accessing Dell EMC support site for documentation and technical assistance.