Next steps
The DDOS Administration Guide describes how to power the system on and off with iDRAC.
The DDOS, PowerProtect DD Virtual Edition, and PowerProtect DD Management Center Security Configuration Guide provides
additional information about accessing security settings in iDRAC.
Configure serial over LAN (SOL)
About this task
The PowerProtect system provides the ability to access the serial console through the iDRAC interface.
Configuring SOL is optional.
If SOL is already enabled on the system, no further action is required.
CAUTION: Do not use iDRAC to change the storage configuration, system settings, or BIOS settings, as making
changes will impact system functionality. Contact Support if changes are required in any of these areas.
CAUTION: Enabling SOL disables the serial console. If SOL is enabled on the PowerProtect DD controller and the
controller subsequently requires servicing, disable SOL and enable the serial console port to prevent confusion
and unnecessary troubleshooting should service personnel attempt to use the serial port to access the system.
Steps
1. In a web browser, type the iDRAC IP address specified during iDRAC configuration.
2. Login with the user name root. The default password is the system serial number on the PSNT.
3. Select Configuration > BIOS Settings > Serial Communications.
4. Verify the following values are configured, and specify any that are not set as listed:
Serial Communication: On with Console Redirection
Serial Port Address: COM1
External Serial Connector: Serial Device 1
Failsafe Baud Rate: 115200
Remote Terminal Type: VT100/VT220
Redirection After Boot: Enabled
5. Click Apply to save any changes.
6. Select iDRAC Settings > Connectivity > Serial Over LAN.
7. Specify the following values if they are not already configured:
Enable Serial Over Lan: Enable
Baud Rate: 115.2 kbps
Channel Privilege Level Limit: Administrator
Redirect Enable: Enable
Escape Key: ^\ (Ctrl + \)
8. Click Apply to save any changes.
9. Select iDRAC Settings > Services.
10. Specify the following values if they are not already configured:
a. Select Enabled for SSH.
b. Verify the Port Number is set to 22.
11. Click Apply to save any changes.
12. Select Configuration > BIOS Settings > Serial Communications.
13. Click Apply and Reboot.
14. Select Maintenance > Job Queue and verify the Configure: BIOS.Setup job is complete.
NOTE: Click Refresh to get the latest status
Configure System for Use 31