Operating System Task
7. On the MDM, modify the SDS port using the command:
scli --modify_sds_port (--sds_id <ID> | --sds_name <NAME> | --
sds_ip <IP>) --new_sds_port <PORT>
For example, for an SDS called "sds198" where the new port number is 7071,
type:
scli --modify_sds_port --sds_name sds198 --new_sds_port 7071
Note: If you modify the SDS port on the MDM first, instead of following the
above procedure, I/O errors might be encountered.
Managing Read Flash cache
This section describes how to manage the Read Flash Cache (RFcache) feature,
which uses PCI flash cards, SSDs and NVMe SSDs for caching of the HDDs in the
SDS, thus accelerating the reads of its HDD devices.
RFcache devices and configuration can be performed during initial system
deployment. If you want to add the use of the RFcache feature after deployment, use
the following work flow:
1. Ensure that the RFcache policy is enabled in the Storage Pool.
2. Enable RFcache in the SDSs where RFcache devices will be added.
3. Add the RFcache devices to the SDSs.
If you want to stop using the RFcache feature, or remove a specific RFcache
device, use the following work flow:
4. Stop RFcache usage in the Storage Pool
5. Remove (command) the RFcache device from the SDS.
6. You can then do one of the following:
l
Physically remove the device from the chassis, and then restart RFcache usage
in the Storage Pool
l
Add the device to the SDS as a storage device
Managing read RAM cache
This section describes how to manage the read RAM cache feature, which is designed
to allocate RAM on nodes for caching of reads or writes. The feature is configured at
the following levels:
l
For a volume (optional)—specific volume to use or not use caching. If you want all
I/Os for a specific volume to use caching, make sure that the volume, the
corresponding Storage Pool, and its SDSs are all configured for using caching.
l
For one or more Storage Pools—caching must be configured at this level for
caching to work in the corresponding SDSs. Write handling mode can also be
configured via the add_storage_pool command, or in a separate command. To
Managing System Objects
Dell EMC VxFlex Ready Node AMS User Guide 143

Table of Contents

Other manuals for Dell EMC VxFlex Ready Node 14G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC VxFlex Ready Node 14G and is the answer not in the manual?

Dell EMC VxFlex Ready Node 14G Specifications

General IconGeneral
BrandDell
ModelEMC VxFlex Ready Node 14G
CategoryServer
LanguageEnglish

Related product manuals