Loading...
Figure 39 Cabinet stack up for R840 servers
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Empty
Empty
R840
R840
R840
R840
R840
R840
R840
Data Switch
Data Switch
Empty
Management Switch
Management Server
R840
R840
R840
R840
R840
R840
R840
R840
Installation of the equipment in the cabinet
Install equipment in the cabinet or rack. Always begin component installation at the bottom of the cabinet and work
upward. Install components at the lowest available space for that component type.
Placement of the equipment in the cabinet is dependent on the type of power distribution units installed in the cabinet.
Refer to the equipment stack up guidelines for each type of power distribution.
l
Install the servers as described in the following sections. Most of the servers will function as VxFlex Ready
Node nodes, and at least one will function as a management server. The procedures for physical installation in
the rack or cabinet apply to both types. Once the servers have been installed, refer to the
VxFlex Ready Node
Hardware Configuration and Operating System Installation Guide
(for your system's operating system), for server
configuration and operating system installation procedures.