18 Installing the Hardware
Specifications
Chassis Physical Design
Environmental Parameters
AC Power Requirements
Parameter C150 Specifications C300 Specifications
Height 15.7 inches (39.88 cm) 22.7 inches (57.66 cm)
Width 17.5 inches (44.45 cm) 17.4 inches (37.58 cm)
Depth 15.3 inches (38.86 cm) 14.4 inches (44.20 cm)
Chassis weight 38 lbs (17.24 kg) with factory 
installed components
86.63 lbs (39.29 kg) fully 
loaded
55 lbs (24.95 kg) with factory 
installed components
152.27 lbs (69.07 kg) fully 
loaded
Parameter C150 Specifications C300 Specifications
Temperature 41° to 104°F (5°C to 40°C) 
(storage temperature)
41° to 104°F (5°C to 40°C) 
(storage temperature)
Maximum thermal 
output
24,566 BTU/hour (for 
100/120V and 200/240V)
4095 BTU/hour (for 100/120V 
and 200/240V)
Relative humidity 5 to 95% (non-condensing) 5 to 95% (non-condensing)
Parameter C150 Specifications C300 Specifications
Nominal input voltage 100 - 240 V 50/60 Hz 100-240 VAC 50/60 Hz
Maximum AC Power 
Supply Input Current 
(Based on 1200 W 
output for 100/120 V 
and 200/240 V lines.)
14 A @ 100 V per AC Power 
Supply
12 A @ 120 V per AC Power 
Supply
7 A @ 200 V per AC Power 
Supply
6 A @ 240 V per AC Power 
Supply
14 A @ 100 V per AC Power 
Supply
12 A @ 120 VAC per AC 
Power Supply
7 A @ 200 VAC per AC Power 
Supply
6 A @ 240 VAC per AC Power 
Supply
Maximum System 
Power Input
4.5 KVA @ 100/120 V
4.4 KVA @ 200/240 V
8.7 KVA @ 100/120 V
8.5 KVA @ 200/240 V