52 | Virtual Server Networking
www.dell.com | support.dell.com
To run a VSN script (Perl or Python) in all connected hypervisor sessions to retrieve
virtual server configurations and update FTOS settings on the switch, enter the
script
command in configuration mode.
To stop a VSN script that is running. enter the
no version of the script script-name
command; for example: no script /usr/pkg/scripts/VSNAgent/VMWare/
VSNAgent.pl
.
Stopping a Hypervisor Session
Disabling a Session
Enter the disable command in HYPERVISOR mode to stop VSN in a hypervisor
session. The
disable command does not remove connectivity with the hypervisor or
remove the session information from the system configuration.
Removing a Session
Use the no hypervisor command in CONFIGURATION mode to delete the
configuration of a hypervisor session from the running configuration. The
no
hypervisor
command deletes the specified configuration and closes an active
hypervisor session, but does not remove the VSN agent from your system.
Command Syntax Command Mode Task
script script-name
CONFIGURATION Run a VSN script in active sessions on VMware and
Xen hypervisors.
For script-name, enter the directory path and
filename where the VSN script is stored on the
switch; for example: script /usr/pkg/
scripts/VSNAgent/VMWare/VSNAgent.pl.
Note: The script command is not supported on S55 switches to run VSN scripts.
Command Syntax Command Mode Task
disable HYPERVISOR Shut down VSN in a hypervisor session.
Command Syntax Command Mode Task
no hypervisor name CONFIGURATION Delete a session from the system.
Enter the name of the hypervisor session that
you want to remove.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell FORCE10 Open Automation and is the answer not in the manual?

Dell FORCE10 Open Automation Specifications

General IconGeneral
SeriesFORCE10
ModelOpen Automation
Jumbo Frame SupportYes
Product TypeSwitch
PortsVaries by model
Switching CapacityVaries by model
Forwarding RateVaries by model
MAC Address Table SizeVaries by model
Power SupplyVaries by configuration
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
DimensionsVaries by model
WeightVaries by model

Related product manuals