32 About Your System
8301h No SMBIOS Not Enough Space In
F000
See "Troubleshooting
System Memory" on
page 121.
If the problem persists, see
"Getting Help" on page 143.
8302h No SMBIOS Not Enough Space In
F000
See "Troubleshooting
System Memory" on
page 121.
If the problem persists, see
"Getting Help" on page 143.
8400h Yes Redirect Memory Error See "Troubleshooting
System Memory" on
page 121.
If the problem persists, see
"Getting Help" on page 143.
F001h No System Event Log Full Check the SEL for details
on the events, then clear
the SEL.
F002h No BMC FRU Header checksum
bad
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
F003h No BIOS Update BMC FRU failed Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
F004h No BMC FRU Internal Area
checksum bad
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
Code Log in BMC Cause Corrective Actions
book.book Page 32 Thursday, March 4, 2010 4:38 PM