Table 34. Expansion card installation order
Card Priority Card Type Form Factor Slot Priority Max Allowed
1 Internal Storage (Integrated Slot) Full Height 7, 6 2
2 External SAS Controllers Full Height 7, 6, 2, 1 2
Low Prole 3, 4, 5 3
3 Fibre Channel 16 Gb Full Height 7, 6, 2 3
Low Prole 3, 4, 5 3
4 Converged Network Adapters Full Height 7, 6, 2 3
Low Prole 3, 4, 5 2
5 40 Gb InniBand Full Height 7, 6, 2 3
Low Prole 3, 4, 5 2
6 10 Gb Ethernet Controllers Full Height 7, 6, 2 3
Low Prole 3, 4 2
Low Prole 3, 4, 5 2
7 Fibre Channel 8 Gb Dual Port Full Height 7, 6, 2 3
Low Prole 3, 4, 5 2
8 Fibre Channel 8 Gb Single Port Full Height 7, 6, 2 3
Low Prole 3, 4, 5 3
9 Fibre Channel 4 Gb Single/Dual Port Full Height 7, 6, 2 3
10 1 Gb NICs Low Prole 3, 4 2
Full Height 7, 6, 2 3
11 External Non-RAID Controller Full Height 7, 6, 2, 1 3
12 NVMe PCIe SSD card Full Height 7, 6, 2, 1 2
Full Height (Low
Prole)
7, 6, 2, 1 (3 ,4) 4
Full Height , Half
Length
6, 1, 2, 7 4
13 Mellanox ConnectX-4 Full Height 6, 1 2
Removing expansion card risers
Prerequisites
CAUTION: Many repairs may only be done by a certied service technician. You should only perform troubleshooting and
simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support
team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety
instructions that are shipped with your product.
1. Follow the safety guidelines listed in the Safety instructions section.
2. Follow the procedure listed in the Before working inside your system section.
102