224 Management: Installing Array Components
Installing the Backplane
1
Align the holes on the backplane with the holes on the array.
2
Tighten the captive screw to secure the backplane to the chassis.
See Figure 15-16 for PowerVault MD3200 or Figure 15-17 for
PowerVault MD3220.
3
Replace the screws that secure the backplane to the chassis.
See Figure 15-16 for PowerVault MD3200 or Figure 15-17 for
PowerVault MD3220.
4
Align the slots on the RAID controller module/power supply cage with the
tabs on the chassis. See Figure 15-15.
5
Push the RAID controller module/power supply cage toward the front of
the array.
6
Replace the screws that secure the RAID controller module/power supply
cage to the chassis.
7
Replace the control panel. See "Installing the Control Panel" on page 220.
8
Replace the power supply/cooling fan modules. See "Installing a Power
Supply/Cooling Fan Module" on page 217.
9
Replace the hard drives. See "Installing a Hard Drive" on page 206.
10
Connect all the cables to the array.
11
Turn on the array and the host server.