Configuration: About Your Storage Array 81
Battery Settings
A smart battery backup unit (BBU) can perform a learn cycle. The smart BBU
module includes the battery, a battery gas gauge, and a battery charger. The
learn cycle calibrates the smart battery gas gauge so that it provides a
measurement of the charge of the battery module. A learn cycle can only start
when the battery is fully charged.
The learn cycle completes the following operations:
Discharges the battery to a predetermined threshold
Charges the battery back to full capacity
A learn cycle starts automatically when you install a new battery module.
Learn cycles for batteries in both RAID controller modules in a duplex system
occur simultaneously.
Learn cycles are scheduled to start automatically at regular intervals, at the
same time and on the same day of the week. The interval between cycles is
described in weeks.
Use the following guidelines to adjust the interval:
You can use the default interval.
You can run a learn cycle at any time.
You can set the learn cycle earlier than the currently scheduled time.
You cannot set the learn cycle to start more than seven days later than the
currently scheduled time.
To change the battery settings perform these steps:
1
In the AMW, select
Storage Array

Change
Battery Settings
.
The
Battery Settings
dialog is displayed.
2
In
Battery location
, select a battery.
3
Check these details about the battery:
Battery status
Battery age
Days until replacement
For more information, see the PowerVault Modular Disk Storage Manager
online help topics.
book.book Page 81 Tuesday, September 27, 2011 3:25 PM

Table of Contents

Other manuals for Dell PowerVault MD3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault MD3200 and is the answer not in the manual?

Dell PowerVault MD3200 Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Storage drive size3.5 \
Storage drive capacity300 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Storage drives installedYes
Installed storage drive typeHDD
Supported storage drive typesHDD & SSD
Total installed storage capacity0.6 TB
Maximum supported storage capacity- TB
Number of storage drives installed2
Number of storage drives supported12
Host ports4
RJ-45 ports quantity1
Chassis type-
Product colorBlack
AC input voltage90-264 V
AC input frequency47/63 Hz
Power supply unit (PSU) capacity600 W
Operating altitude-15 - 3048 m
Storage temperature (T-T)5 - 40 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 85 %
Operating relative humidity (H-H)10 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth561 mm
Width446.3 mm
Height86.8 mm
Weight29300 g