244 Troubleshooting: Your Storage Array Software
22
Determine if there is an excessive amount of network traffic to one or 
more RAID controller modules. 
This problem is self-correcting because the EMW software periodically 
retries to establish communication with the RAID controller modules in 
the storage array. If the storage array was unresponsive and a subsequent 
try to connect to the storage array succeeds, the storage array becomes 
responsive.
For an out-of-band managed storage array, determine if management 
operations are taking place on the storage array from other storage 
management stations. A RAID controller module-determined limit exists 
to the number of Transmission Control Protocol/Internet Protocol 
(TCP/IP) connections that can be made to the RAID controller module 
before it stops responding to subsequent connection attempts. The type of 
management operations being performed and the number of management 
sessions taking place together determine the number of TCP/IP 
connections made to a RAID controller module. This problem is self-
correcting because, after some TCP/IP connections terminate, the RAID 
controller module then becomes responsive to other connection attempts.
23
If the storage array is still unresponsive, a problem may exists with the 
RAID controller modules. Contact your Technical Support representative.
Locating a Physical Disk
You can use the Locate Physical Disk option to physically locate and identify 
one or more of the physical disks in an expansion enclosure by activating 
physical disk LEDs. 
To locate the physical disk:
1
Select the 
Physical
 tab.
2
Select the physical disks that you want to locate.
3
Select 
Physical Disk
 Blink
 Physical Disk
.
The LEDs on the selected physical disks blink.
book.book  Page 244  Tuesday, September 27, 2011  3:25 PM