47 Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
Note: Refer to Isilon Network Design Considerations for more information on specific protocols as they
relate to OneFS.
S4048-ON Leaf 1
S4048-ON Leaf 2
interface range ethernet 1/1/53-1/1/54
decription VLTi
no switchport
no shutdown
vlt-domain 127
backup destination 100.67.170.14
discovery-interface ethernet 1/1/53-1/1/54
interface range ethernet 1/1/53-1/1/54
description VLTi
no switchport
no shutdown
vlt-domain 127
backup destination 100.67.170.15
discovery-interface ethernet 1/1/53-1/1/54
Next, we will create the VLANs. IP addresses and VRRP is configured at the spine layer. On each leaf
switch, the respective VLAN will be defined without an IP address or VRRP.
S4048-ON Leaf 1
S4048-ON Leaf 2
interface vlan100
no shutdown
interface vlan100
no shutdown
Configure the downstream port channels. There will be one port channel for each server as well as a single
port channel for each of the Isilon nodes. Each port channel is assigned an MTU of 9216 to support jumbo
frames, as well configured to allow access to VLAN 100. The vlt-port-channel # command enables
port channels on VLT peers to function as a single port channel.

Other manuals for Dell S3048-ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S3048-ON and is the answer not in the manual?

Dell S3048-ON Specifications

General IconGeneral
Rack Units1U
Form FactorRack-mountable
Input Voltage100-240V AC
Power Supply2 hot-swappable power supplies
ManagementCLI, Web, SNMP
Product TypeSwitch
MAC Address Table Size32K entries
Jumbo Frame SupportYes
Latency< 3 microseconds
Ports48 x 1GbE RJ45, 4 x 10GbE SFP+

Related product manuals