49 Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
S4048-ON Leaf 1
S4048-ON Leaf 2
interface ethernet1/1/1
description Isilon Node 1-10gige-1
no shutdown
channel-group 1 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/3
description Isilon Node 2-10gige-1
no shutdown
channel-group 3 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/5
description Isilon Node 3-10gige-1
no shutdown
channel-group 5 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/17
description Server 1-1
no shutdown
channel-group 101 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/19
description Server 2-1
no shutdown
channel-group 102 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/1
description Isilon Node 1-10gige-2
no shutdown
channel-group 1 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/3
description Isilon Node 2-10gige-2
no shutdown
channel-group 3 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/5
description Isilon Node 3-10gige-2
no shutdown
channel-group 5 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/17
description Server 1-2
no shutdown
channel-group 101 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
interface ethernet1/1/19
description Server 2-2
no shutdown
channel-group 102 mode active
no switchport
mtu 9216
flowcontrol receive on
flowcontrol transmit off
Next, Configure the upstream port channels as well as the corresponding interfaces.

Other manuals for Dell S3048-ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S3048-ON and is the answer not in the manual?

Dell S3048-ON Specifications

General IconGeneral
Rack Units1U
Form FactorRack-mountable
Input Voltage100-240V AC
Power Supply2 hot-swappable power supplies
ManagementCLI, Web, SNMP
Product TypeSwitch
MAC Address Table Size32K entries
Jumbo Frame SupportYes
Latency< 3 microseconds
Ports48 x 1GbE RJ45, 4 x 10GbE SFP+