54 Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
S4048-ON Leaf 3
S4048-ON Leaf 4
interface tengigabitethernet 1/1
description Isilon Node 4-10gige-1
no shutdown
port-channel-protocol LACP
port-channel 1 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/3
description Isilon Node 5-10gige-1
no shutdown
port-channel-protocol LACP
port-channel 3 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/5
description Isilon Node 6-10gige-1
no shutdown
port-channel-protocol LACP
port-channel 5 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/17
description Server 3-1
no shutdown
port-channel-protocol LACP
port-channel 101 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/19
description Server 4-1
no shutdown
port-channel-protocol LACP
port-channel 102 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/1
description Isilon Node 4-10gige-2
no shutdown
port-channel-protocol LACP
port-channel 1 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/3
description Isilon Node 5-10gige-2
no shutdown
port-channel-protocol LACP
port-channel 3 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/5
description Isilon Node 6-10gige-2
no shutdown
port-channel-protocol LACP
port-channel 5 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/17
description Server 3-2
no shutdown
port-channel-protocol LACP
port-channel 101 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/19
description Server 4-2
no shutdown
port-channel-protocol LACP
port-channel 102 mode active
mtu 9216
flowcontrol rx on tx off
Configure the necessary downstream port channels. There will be one port channel for each server as well as
a single port channel for each of the Isilon nodes. Each port channel is assigned an MTU of 9216 to support
jumbo frames. The vlt-peer-lag-port-channel # command ensures that each switch in the VLT is
aware of all port channels and can act accordingly in the event of a switch failure.

Other manuals for Dell S3048-ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S3048-ON and is the answer not in the manual?

Dell S3048-ON Specifications

General IconGeneral
Rack Units1U
Form FactorRack-mountable
Input Voltage100-240V AC
Power Supply2 hot-swappable power supplies
ManagementCLI, Web, SNMP
Product TypeSwitch
MAC Address Table Size32K entries
Jumbo Frame SupportYes
Latency< 3 microseconds
Ports48 x 1GbE RJ45, 4 x 10GbE SFP+