61 Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
-------------------------------------------------------------------------------
1 port-channel1 up 1 1
* 2 port-channel1 up 1 1
vlt-port-channel ID : 3
VLT Unit ID Port-Channel Status Configured ports Active ports
-------------------------------------------------------------------------------
1 port-channel3 up 1 1
* 2 port-channel3 up 1 1
vlt-port-channel ID : 5
VLT Unit ID Port-Channel Status Configured ports Active ports
-------------------------------------------------------------------------------
1 port-channel5 up 1 1
* 2 port-channel5 up 1 1
vlt-port-channel ID : 101
VLT Unit ID Port-Channel Status Configured ports Active ports
-------------------------------------------------------------------------------
1 port-channel101 up 1 1
* 2 port-channel101 up 1 1
vlt-port-channel ID : 102
VLT Unit ID Port-Channel Status Configured ports Active ports
-------------------------------------------------------------------------------
1 port-channel102 up 1 1
* 2 port-channel102 up 1 1
8.1.6 Show VLT mismatch
This command highlights configuration issues between VLT peers. Mismatch examples include incompatible
VLT configuration settings, VLAN differences, the different switch operating system versions and STP
inconsistencies. There should be no output to this command on any switch correctly configured for VLT. If
there is, resolve the mismatch.
S4048-Leaf1# show vlt 127 mismatch
Peer-routing mismatch:
No mismatch
VLAN mismatch:
No mismatch
VLT VLAN mismatch:
No mismatch
8.1.7 Show uplink-state-group
This command is used to validate the UFD status on leaf switches in this topology. Status: Enabled, Up
indicates UFD is enabled and no interfaces are currently disabled by UFD.
S4048-Leaf1# show uplink-state-group 1