Temperature Specifications
Storage 40°C to 65°C (40°F to 149°F)
Continuous operation (for altitude less than 950 m or
3117 ft)
10°C to 35°C (50°F to 95°F) with no direct sunlight on the
equipment.
Maximum temperature gradient (operating and storage) 20°C/h (36°F/h)
The following table describes the relative humidity specifications:
Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere
must be non-condensing at all times.
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
The following table describes the maximum vibration specifications:
Maximum vibration Specifications
Operating 0.26 G
rms
at 5 Hz to 350 Hz (all operation orientations).
Storage 1.88 G
rms
at 10 Hz to 500 Hz for 15 min (all six sides tested).
The following table describes the maximum shock specifications:
Maximum shock
Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y,
and z axes of 40 G for up to 2.3 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y,
and z axes (one pulse on each side of the VxRail) of 71 G for up to 2 ms.
The following table describes the maximum altitude specifications:
Maximum altitude
Specifications
Operating 3048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
The following table describes the operating temperature de-rating specifications:
Operating temperature de-rating
Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft)
above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft)
above 950 m (3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft)
above 950 m (3,117 ft).
Standard operating temperature
The standard operating temperature for altitude less than 950 meters or 3117 feet ranges from 10°C to 35°C (50°F to 95°F)
with no direct sunlight on the equipment.
Expanded operating temperature
The following table describes the expanded operating temperature specifications: