TYBOX
• Carefully read these instructions prior to
installation.
The unit must be installed in compliance with
currently applicable standards.
• Always switch off the mains before installing or
servicing the unit.
• Do not attempt to repair the unit yourself;
after-sales service is available.
• Check that the fastenings are suited to the
surface that the unit will be attached to (sheet
of plaster, brick, etc.).
• The diagrams provided are simplified for greater
clarity.The protective units and other accessories
required by the standards are not illustrated.
Standard UTE NF C15-100 and good practice
must be complied with. Connected or nearby
equipment must not generate excessive
interference (directive 2004/108/EEC).
The room unit must be installed at
a height of approximately 1.5 m,
so that it is within arm's reach for
ease of use. Remove the batteries'
protective tabs (only for
the TYBOX battery version).
To mount the unit on the wall,
it must be separated from its
support.
To do so, unlock the casing, then separate
the thermostat from its base.
Unscrew the terminal box
cover and lift it up as high as it
will go to block it, then
position the base on the wall
running the wires out through
the hole in the cover.
Secure the base using suitable
screws and screw anchors or
fit onto a flush-mounted box
(distance between centres 60 mm).
Connect the control wires.
Close the box and fully tighten the terminal box cover
screw.
1. Room unit mounting
Esempio: versione a batterie.
2. Connection
Wet heating system with thermostat input
or replacement of a 2-wire thermostat
NL
NL
If necessary, remove the
shunt (electric wire)
connecting the two
thermostat input terminals.
If the heating system has
a clock input, do not
mistake it for the
thermostat input.
Heating system with no thermostat input
NL
NL
NL
If the old thermostat is
earthed (green/yellow
wire) or has an
anticipator, remove
the corresponding
wire.
NL
NL
If the boiler
does not have a
thermostat input,
you can directly
control the
circulator pump.
Electric Convectors
A1
A2
NL
NL
Important :
Certain contactors generate interference which may
affect the thermostat's operation.
Where this happens, it is advisable to connect a 230V
RC auxiliary anti-interference device to the terminals of
the contact switch coil(see manufacturer's catalogue).
To control electrical convectors, you MUST use a
power contact switch that is suitable for the total
power to be controlled.
Replacement of a 3-wire thermostat
Technical characteristics
Battery version
• Powered by 2 x LR03 or AAA batteries (supplied)
• Clock save: 30 seconds
Mains version
• 230 V, 50 Hz power supply, ±10%
• Power consumption: 2 VA
• Clock back-up in event of mains outage:
1 hour (by capacitor)
• 2A / 230V output
• Dimensions: WxHxD = 80 x 103 x 25 mm
• Protection index: IP 30
• Install in an environment with normal pollution
levels
• Storage temperature: -10°C to +70°C
• Operating temperature: 0°C to +40°C
Type 1C brownout
• Class II insulation
TYBOX
Daily/weekly programmable thermostat
Installation guide
Battery version
Thermostat
input
example: boiler
Convectors
Contact
switch
Thermostat
input
example: boiler
Mains version
Battery version
Mains version
Battery version
Mains version
Battery version
old thermostat’s
wire
wire to be removed :
- anticipator
- earthed
(green/yellow wire)
old thermostat’s
wire
Mains version
Example of a boiler
terminal box
do not mistake for the
clock input (on some
boiler models)
remove the
shunt
wires to be connected
tothe thermostat
Delta Dore hereby declares that the equipment complies
with the essential requirements and other relevant provi-
sions of the R&TTE Directive 2004/108/CE
(Electromagnetic Compatibility) and 2006/95/EC
(Low Voltage safety).
The EC declaration of conformity for this equipment is
available, on request, from:
"Technical information" department
DELTA DORE - Bonnemain - 35270 Combourg (France)
E-mail : info.techniques@deltadore.com
Because of changes in standards and equipment, the characteristics given in the text
and the illustrations of this document are not binding unless confirmed by our services.
*2702022_Rev.2*

Other manuals for DELTA DORE TYBOX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DELTA DORE TYBOX and is the answer not in the manual?

DELTA DORE TYBOX Specifications

General IconGeneral
MountingWall-mounted
Power Supply2 x AA batteries
Temperature Range5°C to 30°C
Accuracy±0.5°C
PowerBattery-powered
DisplayLCD
CommunicationWired
CompatibilityHeating systems