1
www.deltadore.com
Tybox 137+
Installation and User
Guide
Contents
Installation
The Tybox consists of an X3D
radio transmier and receiver
that come pre-associated.
1. Installing the transmier ............................................................................................ 3
1.1 Location ...................................................................................................................................3
1.2 Mounting ..................................................................................................................................3
2. Installing the receiver .................................................................................................. 4
2.1 Location ...................................................................................................................................4
2.2 Mounting/Connection .......................................................................................................4
3. Time and date seing ................................................................................................. 4
4. Conguring your device (Menu 1) .............................................................................. 5
Menu 1-02 Programme duration ..............................................................................................5
Menu 1-03 Pre-heat activation/deactivation ....................................................................5
Menu 1-04 Selecting the way the receiver relay opens ................................................. 5
Menu 1-08 Controlling the Comfort temperature ............................................................5
Menu 1-09 Anti-seize activation/deactivation .................................................................6
Menu 1-10 Selecting the programming type when connected to Tydom ...............6
5. Conguring your device (Menu 2) ............................................................................. 7
Menu 2-01 Locking or unlocking the seings ..................................................................... 7
Menu 2-02 Correcting the measured temperature .........................................................7
Menu 2-04 Temperature displayed in AUTO mode (setpoint or room).....................7
Menu 2-05 12h/24h time format ..............................................................................................7
Menu 2-06 Automatic summer/winter changeover ........................................................8
Menu 2-07 Days until boiler/heat pump service reminder ...........................................8
Menu 2-08 Control time base ..................................................................................................8
Menu 2-11 Hysteresis seing (if 2-08 = tor) ...........................................................................8
Menu 2-17 Reseing the boiler/heat pump operating hours meter ..........................9
6. Associating to the Tydom app ................................................................................... 9
7. Association with a door/window magnetic contact ............................................ 9
8. Association with a phone transmier ...................................................................... 9

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the DELTA DORE Tybox 137+ and is the answer not in the manual?

DELTA DORE Tybox 137+ Specifications

General IconGeneral
DisplayLCD
Power Supply2 x AA batteries
MountingWall-mounted
ProgrammingDaily and weekly programming
Accuracy±0.5°C
CommunicationWired
CompatibilityHeating systems

Summary

Installation Guide

Installing the Transmitter

Guide to mounting and placing the radio transmitter unit.

Installing the Receiver

Steps for wiring and fixing the receiver unit to the heating system.

Time and Date Setting

Procedure for configuring the device's current time and date.

Configuring Your Device (Menu 1)

Settings for programme duration, pre-heat, relay options, and comfort temperature.

Configuring Your Device (Menu 2)

Settings for locking, temperature correction, display modes, and time format.

Associating to the Tydom App

Steps to connect the Tybox to the Tydom smart home application.

Association with Door/Window Magnetic Contact

Linking a magnetic contact to enable frost protection on window opening.

Association with Phone Transmitter

Guide to pairing the Tybox with a phone transmitter for remote control.

Association with a Repeater

Adding an X3D repeater to improve radio signal strength.

Factory Reset

Restoring default settings for menus to their factory values.

Unpairing/Re-associating Receiver

Troubleshooting receiver and transmitter pairing issues.

Removing Associations from Receiver

Steps to clear stored radio associations from the receiver.

Radio Quality Test

Assessing the transmission quality between transmitter and receiver.

Technical Characteristics

Specifications and technical details of the transmitter and receiver.

Using Your Thermostat

Description of Interface

Overview of the thermostat interface elements and icons.

Automatic Mode (AUTO)

How to operate the thermostat using programmed schedules.

Override Function

Temporarily changing the setpoint temperature until the next programmed point.

Information Button Usage

Accessing temperatures, operating hours, and maintenance reminders.

Time Setting Procedure

Procedure for setting the current time and date on the thermostat.

Adjusting Temperature Settings

Configuring Comfort, Economy, and Frost Protection temperatures.

Quick Programming

Applying pre-set programme profiles (P1-P5).

Customising a Programme

Creating personalised daily or weekly heating schedules.

Programme Verification

Checking the programmed heating schedule.

Return to Initial Programme

Resetting the thermostat to factory default programmes.

Manual Mode Operation

Setting a constant temperature, overriding all programming.

Absence Mode Setup

Setting heating to Frost Protection for periods of absence.

Off Mode Function

Switching off the heating system completely.

Pre-heat Function

Anticipating temperature rise to reach target at scheduled time.

Open Window Detection

Automatic switch to Frost Protection when a window is detected open.

Programming via Tydom App

Functionality when Tybox is linked to Tydom app (menu 1-10=1).

Programming via Tybox Control

Functionality when Tybox controls programming (menu 1-10=0).

Receiver LED Status

Interpreting receiver LED signals for status and faults.

Transmitter Signals and Faults

Understanding transmitter screen messages and fault codes.

Changing Batteries

Procedure for replacing transmitter batteries and impact on settings.