13
12. Technical characteristics
Transmitter
• Power supply using 2 baeries:
2x1.5V Alkaline - Type LR03-AAA
• Class III insulation
• X3D transmission frequency: 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW
• Category II receiver
• Wireless remote control device
• Wireless range of 300 metres outside, varies depending on
the linked equipment (the range can vary depending on the
setup conditions and the electromagnetic environment).
• Wall mounted or table stand unit
• Dimensions: 80 x 103 x 25 mm
• Protection rating: IP 30
• Installation in an environment with normal pollution levels
• Storage temperature: -10°C /+70°C
• Operating temperature from -10°C/+40°C
RF 6000+ receiver
• Power supply 230 V ~, 50 Hz
- Consumption: 0.5 VA
• Class II insulation
• Contact output 5 A max., 230V ~
- Cable length: 1 m
Type 1.C automated action
• Dimensions: 54 x 102 x 20 mm
• X3D transmission frequency: 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW
• Category II receiver
• Wireless remote control device
• Wireless range of 300 metres outside, varies depending on
the linked equipment (the range can vary depending on the
setup conditions and the electromagnetic environment).
• Protection rating: IP x4
• Storage temperature: -10°C /+70°C
• Operating temperature from -10°C/+40°C
• Ball test temperature: 75°C (Housing),
• Rated impulse voltage: 2,500V