Chapter 12  Application Examples|ASDA-A&A+ Series 
12-18     Revision April 2009 
  Definitions of DO Signals   (ON=1, OFF=0) 
Item  DO5  DO4  DO3  DO2  D01  Description 
1 0 0 0 0 0  ALRAM 
2 0 0 0 0 1  SERVO READY 
3 0 0 0 1 0 HOMING (under operation) 
4 0 0 0 1 1  HOME Completed 
5 0 0 1 0 0  CHANGE INDEX  
(under operation) 
6  0  0  1  0  1  INDEX 1  (In position) 
7  0  0  1  1  0  INDEX 2  (In position) 
8  0  0  1  1  1  INDEX 3  (In position) 
9  0  1  0  0  0  INDEX 4  (In position) 
10  0  1  0  0  1  INDEX 5  (In position) 
11  0  1  0  1  0  INDEX 6  (In position) 
12  0  1  0  1  1  INDEX 7  (In position) 
13  0  1  1  0  0  INDEX 8  (In position) 
14  0  1  1  0  1  INDEX 9  (In position) 
15  0  1  1  1  0  INDEX 10  (In position) 
16  0  1  1  1  1  INDEX 11  (In position) 
17  1  0  0  0  0  INDEX 12  (In position) 
18  1  0  0  0  1  INDEX 13  (In position) 
19  1  0  0  1  0  INDEX 14  (In position) 
20  1  0  0  1  1  INDEX 15  (In position) 
21  1  0  1  0  0  INDEX 16  (In position) 
22  1  0  1  0  1  INDEX 17  (In position) 
23  1  0  1  1  0  INDEX 18  (In position) 
24  1  0  1  1  1  INDEX 19  (In position) 
25  1  1  0  0  0  INDEX 20  (In position) 
26  1  1  0  0  1  INDEX 21  (In position) 
27  1  1  0  1  0  INDEX 22  (In position) 
28  1  1  0  1  1  INDEX 23  (In position) 
29  1  1  1  0  0  INDEX 24  (In position) 
30  1  1  1  0  1  INDEX 25  (In position) 
31  1  1  1  1  0  INDEX 26  (In position) 
32  1  1  1  1  1  INDEX 27  (In position) 
NOTE
 
1)  When alarm occurs, DO=0 (all OFF). 
2)  When the servo drive is ready, DO=1 
Call 1(800)985-6929 for Sales