Chapter 7 Servo Parameters|ASDA-A&A+ Series
Revision April 2009 7-27
Group 1: P1-xx Basic Parameters
P1 - 00
PTT External Pulse Input Type Communication Addr.: 0100H
Default: 2 Related Section:
Applicable Control Mode: Pt Section 6.2.1
Unit: N/A
Range: 00 ~ 132 (ASDA-A series)
00 ~ 1132 (ASDA-A+ series)
Settings:
ASDA-A series:
not used
A
B
C
ASDA-A+ series:
D
A
B
C
not used
A: Pulse type
A=0: AB phase pulse (4x)
A=1: CW + CCW pulse
A=2: Pulse + Direction
Other setting: Reversed
B: Input pulse filter
B=0: 500Kpps
B=1: 200Kpps
B=2: 150Kpps
B=3: 80Kpps
This setting is used to suppress or reduce the
chatter caused by the noise, etc. However, if the
instant input pulse filter frequency is over high,
the frequency that exceeds the setting value will
be regarded as noise and filtered.
C: Logic type
0=Positive Logic 1=Negative Logic
Pulse Type
Forward Reverse Forward Reverse
AB phase pulse
CW + CCW pulse
Pulse + Direction
Input pulse interface Max. input pulse frequency
Line driver 500Kpps
Open collector 200Kpps
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com

Table of Contents

Other manuals for Delta Electronics ASDA-A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics ASDA-A Series and is the answer not in the manual?

Delta Electronics ASDA-A Series Specifications

General IconGeneral
BrandDelta Electronics
ModelASDA-A Series
CategoryServo Drives
LanguageEnglish

Related product manuals