DELTA ELEKTRONIKA BV SM3000
Page 4 - 8 OPERATING MAINTENANCE TROUBLE SHOOTING CALIBRATING 1991, rev. May 2008
CALIBRATION
1) GEN ERAL
The power supplies are factory cali-
brated and nor mally need no further
cal i bra tion.
2)
METER CAL I BRA TION
DIG I TAL ME TERS
The zero indication can be calibrated
with R712 and R716, the full scale in di-
cation can be calibrated with R706 and
R708 on P388 (see fig. 4 - 19).
3)
SPE CIAL CAL I BRA TIONS
The fol low ing cal i bra tions must be
done by qual i fied per son nel only.
Wrong cal i bra tion causes mal func tion.
These cal ibrations are only needed af -
ter spe cial re pairs. Warn ing ! Dam age
caused by wrong cal ibration is not war -
ranted.
CAL I BRATING MAX. CUR RENT
RANGE or CAL IBRATING CC MON I-
TOR FULL SCALE.
The max. out put cur rent can be cali-
brated with R686. R686 is lo cated on
P432 (see fig. 4 - 20).
Program CC in put with exactly 5.00 V.
Set output voltage to a low value, en -
suring the power supply is in CC mode.
Measure the output cur rent with an ac -
curate shunt. Cal ibrate the cur rent with
R686 ex actly on the rated max. cur rent.
Warn ing! Wrong calibration can dam -
age the unit.
CAL I BRATING THE CC MON I TOR
OFF SET.
With R652 on P384 the offset of the CC
mon i tor volt age can be cal i brated (see
fig. 4 - 21). The unit has to be un loaded,
the out put voltage set on a low value.
Measure the offset voltage of the CC
mon i tor on the prog. con nec tor. Cal i -
brate the off set on a neg ative value be -
tween –10 mV and zero mV.
Warn ing! wrong cal i bra tion can
damage the unit.
4)
SPARE PARTS
When or dering spare parts please
state: Model, Se rial num ber, Compo-
nent num ber and Com ponent de scrip-
tion.
Ex am ple:
- Model .............SM 30-100 D
- Se rial no. ........Sn821701900017
- BSU no...........Bs816802900036
- Com po nent.....D300
- Description. ....BYV52-PI-200
fig. 4 - 19 Me ter cal ibration with 25-turn potmeters on P388
fig. 4 - 20 Calibrating max. current on P432
fig. 4 - 21 On P384, CC mon itor can be calibrated

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Elektronika SM 3000 Series and is the answer not in the manual?

Delta Elektronika SM 3000 Series Specifications

General IconGeneral
BrandDelta Elektronika
ModelSM 3000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals