Electrical Installation
23
NOTES:
Turn-on input voltage is 85VAC (QuiQ
1000) and 110VAC (QuiQ 1500).
Turn-off input voltage is 80VAC (QuiQ
1000) and 100VAC (QuiQ 1500).
Charger may handle a much
wider range of input frequencies.
Contact Delta-Q Technologies if a
non-standard frequency input is
anticipated.
A Class A Ground Fault Circuit
Interrupter (GFCI) is recommended
for use with the charger if there is a
risk of electric shock while handling
the charger.
The QuiQ Series charger has been
tested with a number of portable
AC power generators. DQDB and
newer chargers can be used with
virtually any generator rated 2kW or
higher. Lower rated generators may
also work as ratings vary widely,
test the charger under load with

Questions and Answers: