ASDA-A2 Chapter 6 Control Mode of Operation
Revision February, 2017 6-23
Settings:
The setting value of the second low-frequency vibration suppression. If
P1-28 is set to 0, then it will disable the second low-frequency filter.
P1-28
VSG2 Low-frequency Vibration Suppression Gain (2)
Address: 0138H
0139H
Operational
Interface:
Panel / Software Communication
Related Section:
6.2.9
Default:
0
Control
Mode:
PT / PR
Unit:
-
Range:
0 ~ 9 (0: Disable the second low-frequency
filter)
Data Size:
16-bit
Format:
Decimal
Settings:
The second low-frequency vibration suppression gain. The bigger value
it is, the better the position response will be. However, if the value is set
too big, the motor will not be able to smoothly operate. It is suggested to
set the value to 1.