EasyManua.ls Logo

Delta ASD-A2-0721 Series - Page 358

Delta ASD-A2-0721 Series
721 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-107
Settings
1~50Hz: Low stiffness, low response
51~250Hz: Medium stiffness, medium response
251~850Hz: High stiffness, high response
851~1000Hz: Extremely high stiffness, extremely high response
NOTE
1According to the speed loop setting of P2-31, the servo drive sets
the position loop response automatically.
2The function is enabled via parameter P2-32. Please refer to
Chapter 5.6 for corresponding bandwidth size of the setting value.
P2-32
AUT2 Tuning Mode Selection
Address: 0240H
0241H
Operational
Interface
Panel / Software Communication
Related Section:
5.6 and 6.3.6
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ 0x2
Data Size
16-bit
Format
Hexadecimal
Settings
0: Manual Mode
1: Auto Mode (continuous adjustment)
2: Semi-auto Mode (non- continuous adjustment)