ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-139
P3-04 CWD Communication Timeout
Address: 0308H
0309H
Operational
Interface
Panel / Software Communication
Related Section:
9.2
Default
0
Control
Mode
ALL
Unit
sec
Range
0 ~ 20
Data Size
16-bit
Format
DEC
Settings
If the setting value is not 0, enable communication timeout
immediately. If it is set to 0, disable the function.
P3-05 CMM Communication Mechanism
Address: 030AH
030BH
Operational
Interface
Panel / Software Communication
Related Section:
9.2
Default
0
Control
Mode
ALL
Unit
-
Range
0x00 ~ 0x01
Data Size
16-bit
Format
Hexadecimal
Settings
Communication port can select one or more than one communications.
Communication Interface
0: RS232
1: RS485