EasyManua.ls Logo

Delta ASD-A2R-0221 Series - Page 322

Delta ASD-A2R-0221 Series
660 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 ParametersASDA-A2R Series
8-90 Revision December, 2014
P2-21 DO4 DO4 Functional Planning
Address: 022AH
022BH
Operational
Interface
Panel / Software Communication
Related Section:
Table 8.2
Default
105
Control
Mode
ALL
Unit
-
Range
0 ~ 0x013F (the last two codes are DO
code)
Data Size
16bit
Format
HEX
Settings
Please refer to the description of P2-18
P2-22 DO5 DO5 Functional Planning
Address: 022CH
022DH
Operational
Interface
Panel / Software Communication
Related Section:
Table 8.2
Default
7
Control
Mode
ALL
Unit
-
Range
0 ~ 0x013F (the last two codes are DO
code)
Data Size
16bit
Format
HEX
Settings
Please refer to the description of P2-18
P2-23 NCF1 Resonance Suppression (Notch filter) (1)
Address: 022EH
022FH
Operational
Interface
Panel / Software Communication
Related Section:
6.3.7
Default
1000
Control
Mode
ALL
Unit
Hz
Range
50 ~ 1000
Data Size
16bit

Table of Contents

Related product manuals