EasyManua.ls Logo

Delta ASD-A2R-0221 Series - Page 355

Delta ASD-A2R-0221 Series
660 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 ParametersASDA-A2R Series
Revision December, 2014
8-123
P3-07 CDT Communication Response Delay Time
Address: 030EH
030FH
Operational
Interface
Panel / Software Communication
Related Section:
9.2
Default
0
Control
Mode
ALL
Unit
1ms
Range
0 ~ 1000
Data Size
16bit
Format
DEC
Settings
Delay the time of communication response from servo drive to
controller
P3-08
MNS Monitor Mode
Address: 0310H
0311H
Operational
Interface
Panel / Software Communication
Related Section:
9.2
Default
0000
Control
Mode
ALL
Unit
-
Range
Shown as below
Data Size
16bit
Format
HEX
Settings
The setting of monitor mode is divided into L and H.
(hexadecimal):
Item
L H
Function
Low-speed
monitoring
time
Monitor Mode
Range 0 0 0 ~ F 0 ~ 3