Chapter 8 ParametersASDA-A2R Series
8-272 Revision December, 2014
PM-30 The Max. Current of PM Motor
Address:
Applicable
motor type:
SPM, IPM
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
0x0100
Unit:
0.01A
Range:
0 ~ the rated current of servo drive
Data Size:
16bit
Format:
DEC
Settings:
PM-31 PM Motor Rated Speed
Address:
Applicable
motor type:
SPM, IPM
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
3000
Unit:
rpm
Range:
0 ~ 6000
Data Size:
16bit
Format:
DEC
Settings:
PM-32 The Max. Speed of PM Motor
Address:
Applicable
motor type:
SPM, IPM
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
5000
Unit:
rpm
Range:
0~6000
Data Size:
16bit