ASDA-M Chapter 8 Parameters
Revision December, 2014
8-161
Settings
When CAP stops, it means the number of data that expect to
capture (readable and writable)
When CAP activates, it means the number of data that has not
been captured (read-only); Every time, when it captures one data,
the value of P5-38 will minus one. When the value is 0, it means
the capturing is completed.
NOTE
The number of data which is used by COMPARE, CAPTURE and
E-Cam cannot exceed 1500.
P5-39
CACT
CAPTUREActivate CAP Control
Address: 054EH
054FH
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.11.1
Operational
Interface
Panel / Software Communication
Default
0x2010
Control
Mode
ALL
Unit
-
Range
0x0000 ~ 0xF13F
Data Size
16bit
Format
HEX
Settings
X See the following table