EasyManua.ls Logo

Delta ASD-M-1521 Series - Page 364

Delta ASD-M-1521 Series
645 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASDA-M Chapter 8 Parameters
Revision December, 2014 8-133
P4-08
PKEY
Input Status of the Drive Keypad
(Read-only)
Address: 0410H
0411H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
-
Control
Mode
ALL
Unit
-
Range
(Read-only)
Data Size
16bit
Format
HEX
Settings
The aim is to check if the five Keys, MODE, UP, DOWN, SHIFT
and SET can work normally. This parameter is also used to check
if the Keys are all functional when producing servo drives.
P4-09
MOT Digital Output Status (Read-only)
Address: 0412H
0413H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 4.4.5
Operational
Interface
Panel / Software Communication
Default
-
Control
Mode
ALL
Unit
-
Range
0 ~ 0x1F
Data Size
16bit
Format
HEX
Settings
Note: There is no difference whether read by panel or
communication.

Table of Contents

Related product manuals