ASDA-M Chapter 8 Parameters
Revision December, 2014 8-141
Settings
When the voltage of DC BUS is lower than P4-24*
2
, the
undervoltage alarm occurs.
P4-25 SFSW Special Function Switch
Address: 0432H
0433H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0x00000000
Control
Mode
ALL
Unit
-
Range
0x00000000 ~ 0x00000001
Data Size
32bit
Format
HEX
Settings
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Software limit switch in
speed mode
Sofware limit switch in speed mode
0: In speed mode, disable software limit protection and show
alarms only
1: In speed mode, enable software limit protection and show
alarms