ASDA-M Chapter 8 Parameters
Revision December, 2014 8-175
P5-62 POV2 Target Speed Setting #2
Address: 057CH
057DH
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface
Panel / Software Communication
Default
100.0 1000
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16bit
Format
DEC
Example
1 = 1 r/min 10 = 1 r/min
Settings
The 3
rd
target speed of PR mode
P5-63 POV3 Target Speed Setting #3
Address: 057EH
057FH
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface
Panel / Software Communication
Default
200.0 2000
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16bit
Format
DEC
Example
1 = 1 r/min 10 = 1 r/min
Settings
The 4
th
target speed of PR mode