EasyManuals Logo

Delta DVP-SS2 User Manual

Delta DVP-SS2
1006 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #634 background imageLoading...
Page #634 background image
3. Instruction Set
3-513
Program Example1: Immediate stop high-speed pulse output by external interrupt
1. Adopt X4 as the input for external interrupt and I401 (rising-edge trigger) as the interrupt
pointer. Set target number of feedbacks = 50,000; target frequency = 100kHz; pulse output
device: Y0, Y1 (CH0); start/end frequency (D1340) = 100Hz; ramp-up time (D1343) = 100ms;
ramp-down time (D1348) = 100ms; percentage value (D1131) = 100; present value of output
pulses (D1030, D1031) = 0.
MOV
MOV
MOV
K100
K100
K100
D0
M1002
D1131
D1343
D1348
SET
DMOV K0
D1030
EI
FEND
IRET
END
DCLLM
X4
K50000
K100000
Y0
INC
M1534
M0
M1000
I401
MOV
K100 D1340
MOV
K100
D1343
MOV
K100 D1343
Execution results:
100kHz
D1340
D1343
X4 = OFF --> ON
D1340
D1348
Specified number of output pulses: 50,000
Actual number of output pulses (D1030, D1031) = K51000
Frequency
Y0 output stops
Time
Pulse number