2. Programming Concepts
D
Content
EX2
SS2
SA2
SE
SX2
Attrib.
Latch
-ed
Default
M1611 to enable this function. Or you can
with PLC Link via this register.
D1988
Set the maximum frequency of the ramp
up/down for the fixed slope of Y1 in D1988
(Low word). You need to use M1606 to
enable this function. Or you can with PLC
Link via this register. Available for
ES2/EX2: V3.28, ES2-E: V1.00,
12SA2/SX2: V2.82, SE: V2.00, 28SA2:
V2.90 or later.
ES2/
EX2
╳ ○ ○
- - - RW NO -
Set the maximum frequency of the ramp
up/down for the fixed slope of CH2 (Y4/Y5)
in D1988 (Low word). You need to use
M1610 to enable this function. Or you can
with PLC Link via this register.
EC5
╳ ○ ○
- - - RW NO -
D1989
Set the maximum frequency of the ramp
up/down for the fixed slope of Y1 in D1989
(High word). You need to use M1606 to
enable this function. Or you can with PLC
Link via this register. Available for
ES2/EX2: V3.28, ES2-E: V1.00,
12SA2/SX2: V2.82, SE: V2.00, 28SA2:
V2.90 or later.
ES2/
EX2
╳ ○ ○
- - - RW NO -
Set the maximum frequency of the ramp
up/down for the fixed slope of CH2 (Y4/Y5)
in D1989 (High word). You need to use
M1610 to enable this function. Or you can
with PLC Link via this register.
EC5
╳ ○ ○
- - - RW NO -
D1990
Set the maximum frequency of the ramp
up/down for the fixed slope of Y3 in D1990
(Low word). You need to use M1607 to
enable this function. Or you can with PLC
Link via this register. Available for
ES2/EX2: V3.28, ES2-E: V1.00,
12SA2/SX2: V2.82, SE: V2.00, 28SA2:
V2.90 or later.
ES2/
EX2
╳ ○ ○
- - - RW NO -
Set the maximum frequency of the ramp
up/down for the fixed slope of CH3 (Y6/Y7)
in D1990 (Low word). You need to use
M1611 to enable this function. Or you can
with PLC Link via this register.
EC5
╳ ○ ○
- - - RW NO -
D1991
Set the maximum frequency of the ramp
up/down for the fixed slope of Y3 in D1991
(High word). You need to use M1607 to
enable this function. Or you can with PLC
Link via this register. Available for
ES2/EX2: V3.28, ES2-E: V1.00,
12SA2/SX2: V2.82, SE: V2.00, 28SA2:
V2.90 or later.
ES2/
EX2
╳ ○ ○
- - - RW NO -
Set the maximum frequency of the ramp
up/down for the fixed slope of CH3 (Y6/Y7)
in D1991 (High word). You need to use
M1611 to enable this function. Or you can
with PLC Link via this register.
EC5
╳ ○ ○
- - - RW NO -
D1994
Remaining times for PLC password setting
on DVP-PCC01
â—‹ â—‹ â—‹ â—‹
0
D1995
Data length for PLC ID Setting on DVP-
PCC01
â—‹ â—‹ â—‹ â—‹
0 - - R/W NO 0
D1996
1
st
Word of PLC ID Setting for DVP-PCC01
(Indicated by Hex format corresponding to
â—‹ â—‹ â—‹ â—‹
0 - - R/W NO 0