Operation and installation manual SOLIVIA 2.5 EU G3
Country selection
Increase network ID Decrease network ID
Down *
Up *
Enter network ID
ENTER *
ESC *
Select country
Next country Country before
Down *Up *
ENTER *
Normal mode
* Timeout if no key is pressed (within 5 minutes)
Possible countries:
Belgium
Czech Republic
France
French island (60 Hz)
DE VDE
DE LVD
Greece continent
Greece island
Italy (50 Hz / 49 Hz)
Italy (51 Hz / 49 Hz)
Portugal
Spain (51 Hz / 49 Hz)
Spain (51 Hz / 48 Hz)
United Kingdom
AC Pwrlim [W]
3456 W
Set AC Pwrlim. ?
YES | NO
ENTER *
YES
NO
ESC *
ESC *
Please note, that once the country has been selected and con rmed, it is only possible to change
the country by following the steps as listed below:
1. Please click ESC + Down button for few seconds to get the key information.
2. Provide the key code to the Solar Support Team at support@solar-inverter.com to get the PIN
code (valid for one use only!).
3. Once you get the PIN code, you need to press ESC + Down button.
4. Then, you will be asked to insert the PIN code and to con rm it twice.
5. After con rmation, you will then be able to select the desired country.
Note: These steps must be executed without interruption. Otherwise, you will stay in the country
selection mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta SOLIVIA 2.5 EU G3 and is the answer not in the manual?

Delta SOLIVIA 2.5 EU G3 Specifications

General IconGeneral
BrandDelta
ModelSOLIVIA 2.5 EU G3
CategoryInverter
LanguageEnglish

Related product manuals