21
ENGLISH
Operation and installation manual SOLIVIA 2.5 EU G3
Autotest Passed
Start Autotest?
The rst line shows the actual autotest status which could be „passed” or „failed”. Pressing the
autotest routine starts. The rst test performed is the OVT, over voltage test, which verify the over
voltage protection. The display shows:
7.3.1 Autotest (only for Italy)
This function is available only for the Italian country.
The inverter is supplied with an autotest function able to verify the correct operation of the interface
protection.
In the main menu, using buttons , select the autotest menu. The display shows, for example:
L: 262 V < 0.1 S
Start OVT test?
The rst line shows the actual over voltage limit and detection time settings according to the stan-
dards. Pressing the test starts. Pressing „ESC” the display goes back to the main menu. Test
starts by pressing or automatically after 10 seconds.
The display shows, for example:
L: 262 V OVT
A: 230 V RUN
L: 230 V 0.044 S
A: 230 V OV pass
L: 186 V < 0.2 S
Start UVT test?
After few seconds needed from the inverter to switch to the test mode, the limit „L:“ will decrease till
crossing the actual measured grid voltage „A:“. Reached this condition the inverter display shows,
for example:
If the test is con rmed, the inverter performs the UVT test, under voltage test, which verify the under
voltage protection. The display shows:
The rst line shows the actual under voltage limit and detection time settings according to the
standards. Pressing the test starts. Test starts also automatically after 10 seconds if is not
pressed.
If has been pressed the display shows, for example:
L: 186 V UVT
A: 230 V RUN
The rst line shows the limits according the standard. The second line shows the actual measured
trip limit and the test status if positive (pass). (If the test is negative (failed), press „ESC“ and the
display goes back to the main menu and the inverter is in error condition.).
Pressing the test is con rmed and the autotest routine continue. If is not pressed, the result
is shown for 10 seconds. After this time, the result is con rmed automatically.